what is the full form of ups ?
? uninterruptible power supply? unwanted power supply? unused power supply? uninstall power supply
which is provides uninterrupted power to the load ?
? smps? ups? rectifier? regulator
what is the function of relays in ups ?
? voltage increase? voitage decrease? electrically operate switch? current decrease
what is the measured unit of ups output rating ?
? voltage? amphere? volt ampere? farad
which one is used for to smooth out and filter fluctuations in voltage in ups ?
? bettery? relay? electrolytic capacitor? fans
what is the life expectancy of battery in ups ?
? 10-20 years? 5-10 years? 8-10 years? 3-5 years
what is the full form of mov in ups ?
? main oxide varistors? metal oxide voltage? metal oxide varistors? metal oxide value
which is most commonly used battery type in a ups ?
? dry cell? flat cell? round cell? valve -regulated lead acid battery
what is the ambient temperature for the rated capacity of a ups battry ?
? 25'c? 25'f? 10'c? 10'f
which one is general category of modern ups system ?
? serious ups? netutral ups? line interactive ups? extreme ups
what is the full form of smf battary ?
? special multi free? sealed maintenance free? special mains free? sealed multi free
what is the full form of eol in ups ?
? lnital of life? earning of life? expert of life? end of life
which in used i the rotating type ups system to supply the mains ?
? altermator? dc moniter? dc generator? battery bank
what is the minimum time period for check water level of the battry ?
? every 50 days? every 15 days? every 5 days? every 30 days
what is the efficiency of standby ups type ?
? high? very high? low? low - medium
which battry do not require any kind of regular maintenance ?
? automobile batteries? lead acid batteries? smf batteries? nickel-cadmium batteries
which is used for checked by battery capacity ?
? electric tester? neon tester? volt meter? load tester
which is affected by irregular maintenance ?
? battery? relay? fan? capacitor
which test is used to ascertain whether the battery plates are defective ?
? opan volt test? cadmium test? high discharge test? specific gravity te
what is the character must be a battery electrode ?
? a semi conductor? an insulator? a good conductro? a bad cond
which primary cell have the lowest voltage ?
? lithium? zinc chloride? mercury? carbon zinc
which is used in electrolytes, to prevent local action in battery ?
? pump water? distilled water? tap water? mineral water
which is the example of battery back up ?
? cpu? ups? smps? electrolyte
what is the backup duration for 600 va ups ?
? 5 to 10 minites? 1 to 5 minites? 15 to 20 minites? 30 to 45 minites
what is the battery back up ?
? to increase memory? to reduce the memory? to provide additional memory? to provide continuous power