Theory - 64 :- Cathode Ray Oscilloscope (CRO), working and its Applications

Cathode Ray Oscilloscope (CRO)

Definition

The cathode ray oscilloscope (CRO) is a type of electrical instrument which is used for showing the measurement and analysis of waveforms and other electronic and electrical phenomena. It is an extremely quick X-Y plotter that shows the input signal versus another signal or versus time. The CROs are used to analyze the waveforms, transient, phenomena, and other time-varying quantities from an extremely low-frequency variety to the radio frequencies.

Construction of CRO

The building of CRO consists of the following:

  1. Cathode Ray Tube
  2. Electronic Gun Assembly
  3. Deflecting Plate
  4. Fluorescent Screen For CRT
  5. Glass Envelop
  6. Cathode Ray Tube

 


  1. Cathode Ray Tube 

The CRO is the vacuum tube and the primary function of this gadget is to change the signal from electrical to visual. This tube consists of the electron weapon along with the electrostatic deflection plates. The primary function of this electron gun is used to generate a concentrated electronic ray that accelerates to high frequency.

The vertical deflection plate will turn the ray up and down whereas the horizontal ray moved the electron beams from the left side to the right side. These actions are autonomous from each other and therefore the ray might lie anyplace on the display.

     2. Electronic Gun Assembly

The primary function of the electron gun is to produce the electrons to form them into a ray. This gun generally includes a heating unit, a grid, cathode, and anodes like speeding up, pre-accelerating, and focusing.

At the cathode end, the strontium and barium layers are deposited to acquire the high electrons emission of electrons at the moderate temperature level, the layers of barium, and are transferred at the end of the cathode. There are two techniques of focusing on the electron beam. These techniques are.

    • Electrostatic focusing.
    • Electro-magnetic focusing.

The CRO uses an electrostatic focusing tube.

    3.  Deflecting Plate

The electron beam after leaving the electron gun passes through the two sets of the deflecting plate. The pair of plate producing the vertical deflection is called a vertical deflecting plate or Y plates, and the pair of the plate which is utilized for horizontal deflection is called horizontal deflection plate or X plates.

   4.  Fluorescent Screen of CRT

In the CRT, the front face is called the faceplate, For the CRT screen, it is flat and its size is about 100mm × 100mm. The CRT screen is rather bent for bigger displays and the formation of faceplate can be done by pressing the molten glass into a form and after that heating it.

The inner face of the faceplate is covered by using phosphor crystal to alter the energy from electrical to light. Once an electronic device’s ray hits phosphor crystal, the energy level can be boosted, and thus light is produced throughout the phosphorous formation, so this occurrence is referred to as fluorescence.

    5. Glass Envelope

It is an incredibly left cone-shaped form of construction. The inside faces of the CRT among the neck along with the display are covered through the aquadag. This is a conducting material that acts like a high-voltage electrode. The surface of the coating is connected electrically towards the accelerating anode to help the electron to be at the center.


Working of CRO

When the electron is injected through the electron gun, it passes through the control grid. The control grid controls the intensity of electrons in the vacuum tube. If the control grid has high negative potential, then it permits only a few electrons to travel through it. Hence, the dim spot is produced on the lightning screen. If the negative potential on the control grid is low, then the bright spot is produced. Thus, the intensity of light depends on the negative potential of the control grid.

After moving the control grid, the electron beam passing through the focusing and accelerating anodes. The accelerating anodes are at a high positive potential and thus they assemble the beam at a point on the screen.

After moving from the accelerating anode, the beam comes under the impact of the deflecting plates. When the deflecting plate is at zero potential, the beam produces an area at the Centre. If the voltage is applied to the vertical deflecting plate, the electron beam focuses upward and when the voltage is used horizontally the spot of light will be deflected horizontally.


Applications of CRO

 While various, a CRO can be used for the following purposes:

  •  To identify the amplitude of a waveform.
  • Comparison between the phases and frequencies of electrical signals.
  • Assist procedure capacitance and inductance values.
  • In the medical field and medical practice, it can be utilized for keeping an eye on different body specifications like heartbeat rates and nervous responses.
  • It is likewise used for understanding the waveforms, short-term phenomenon, and other time-varying quantity from a really low-frequency range to the radio frequencies.